MidNite Solar MNPV6-250 Combiner Box

SKU: 510-0132

Details

Midnite Solar, Combiner box, will accept 3 -300V Breakers High voltage MNPV6-250V



The MNPV6 Disco is extremely adaptable. It's ETL approved for both AC and DC. This helps you to customize it for a number of purposes. It can be used with up to six MidNite Solar 150 volt DC breakers. For a grid-tie disconnect, the combiner can be used with one of Midnite Solar's 600 volt DC breakers. To make a full disconnect for a grid-tie inverter, combine a 240 volt AC breaker with a 600 volt DC breaker. Rated for a load break.


This configuration makes a compact Grid Tie disconnect for those applications where the built-in switch won’t do the trick. MidNite Solar has 16 and 20 amp 600VDC breakers. They stock 120V and 240VAC breakers.


These DIN-mount 150 V circuit breakers, MidNite 300 VDC breakers, Midnite 600 VDC breakers, or 600 VDC fuse holders for grid-tie arrays can fit in these powder-coated aluminum rainproof array combiners. A plastic cover, which can be knocked out for either breakers or fuse holders, offers a dead front for protection. A negative, as well as a ground busbar, is used. The aluminum NEMA 3R enclosures can be placed at angles ranging from 90 degrees to 14 degrees (vertical to 3/12 slope). For the United States of America and Canada, it is classified as UL 1741. Fuse holders and breakers are not included.


Three single-pole 150 VDC (MNEPV) breakers or two 600/1,000 VDC fuse holders can be used in the MNPV3. A 60 A positive busbar, a six-position PV-negative busbar, and a six-position ground busbar are included in this package. As a disconnect, a single 300 VDC breaker rated from 7 to 50 A can be used (no combining busbar).


Six single-pole 150 VDC breakers or four 600/1,000 VDC fuse holders can be used with the MNPV6. A 15-position PV-negative bus bar, a 14-position ground bus bar, a 120 A positive bus bar for breakers, and an 80 A bus bar for fuses are included. Two grid-tie inverters or two charge controllers can be assisted by splitting the positive busbar. A popular negative PV bus can be found in most charge controllers and grid-tie inverters (except Schneider XW and BlueSky).


For charge controllers that accept input voltages up to 300 VDC, the MNPV6-250 can hold up to three single-pole 300 VDC circuit breakers.


12 single-pole 150 VDC breakers or ten 600/1,000 positive VDC fuse holders can be used with the MNPV12. It has a PV-negative busbar with 15 positions, a land busbar with 15 positions, and two 200 A Plus busbars for breakers or fuses. To assist two grid-tie inverters or two charge controllers, positive busbars can be combined or split. A popular negative PV bus can be found in most charge controllers and grid-tie inverters (except Schneider XW and BlueSky).


For charge controllers that accept input voltages up to 300 VDC, the MNPV12-250 can hold up to six single-pole 300 VDC circuit breakers.


16 single-pole 600 VDC fuse holders will fit in the MNPV16. Includes a PV-negative busbar with 21 positions, a land busbar with 18 positions, and 240 A positive and negative busbars.


Up to 24 single-pole, 150 VDC breakers can be accommodated by the MNPV16-24 PV combiner. Two dozen 10 A breakers, sixteen 15 A breakers, twelve 20 A breakers, or eight 30 A breakers can be accommodated by the 240 A busbar. Thanks to its ability for larger cables, this combiner is suitable for combining Aquion battery stacks.


12 single-pole 300 VDC breakers can be used with the MNPV16-250. Includes a PV-negative busbar with 21 positions, a land busbar with 18 positions, and 240 A positive and negative busbars.


The MNPVxx-1000 combiners need 1,000 VDC fuse holders and fuses, which must be purchased separately. Just two output circuits can be separated from the MNPV10-1000.


Features

  • User Friendly - It can be seen in a variety of cases. To a 14-degree incline (3/12 roof pitch), use a vertical wall rack, pole mount, or sloped roof mount. It can act as an AC micro combiner or a DC off-grid combiner.
  • Efficient- Nema 3R aluminum enclosure (no rust, won’t turn to dust). Has six spaces for virtually any configuration needed.
  • Safety - Uses Midnite Solar's Din Rail circuit breakers.